產品型(xing)號:RW12
產品特點:10KV跌(die)落(luo)保(bao)險(xian)廠家它提供(gong)了(le)壹種(zhong)用(yong)於(yu)在(zai)操(cao)作10kV高壓熔斷器時進(jin)行夾(jia)持的(de)器具,使(shi)用(yong)它操(cao)作人(ren)員(yuan)進(jin)行取(qu)下、安(an)裝(zhuang)10kV高壓熔斷器時操(cao)作方(fang)便簡(jian)單省時省力,同(tong)時(shi)在(zai)壹(yi)定程度(du)上保(bao)證了(le)安全(quan)受(shou)到操(cao)作人(ren)員(yuan)的歡迎(ying)。
10KV跌(die)落(luo)保(bao)險(xian)廠家以往的(de)變電(dian)所設計(ji)中,由(you)於(yu)受10kV配(pei)電(dian)設備技(ji)術(shu)參數(shu)的(de)制(zhi)約,10kV配(pei)電(dian)裝置壹般都(dou)采用(yong)戶內布置方式(shi),電(dian)壓互(hu)感器選用(yong)RN2-10或(huo)RN5-10型(xing)戶內高壓限流熔(rong)斷器作過(guo)載和短(duan)路(lu)保(bao)護(hu)之(zhi)用(yong)。近年來,隨(sui)著技術(shu)水(shui)平的(de)不斷進(jin)步(bu),10kV配(pei)電(dian)設備的(de)技(ji)術(shu)參數(shu)有了(le)很大(da)的(de)提高,RW10-35,出(chu)現了(le)很多(duo)適(shi)應(ying)戶外運行的(de)設備,為(wei)變電(dian)所采用(yong)全(quan)戶外布(bu)置方式(shi)提供(gong)了(le)可能(neng)。在(zai)農(nong)村(cun)電(dian)網改(gai)造(zao)中(zhong),110kV、35kV變電(dian)所采用(yong)全(quan)戶外布(bu)置已成為(wei)壹(yi)種(zhong)經(jing)常采用(yong)的方式(shi)。RW10-35,但(dan)是,10kV配(pei)電(dian)裝置采用(yong)全(quan)戶外布(bu)置後,10kV電(dian)壓互(hu)感器(包(bao)括(kuo)母(mu)線用(yong)電(dian)壓互(hu)感器和出(chu)線側(ce)用(yong)電(dian)壓互(hu)感器)壹(yi)次(ci)側(ce)的(de)保(bao)護(hu)電(dian)器的選(xuan)擇,RW10-35,卻(que)成了(le)讓設計(ji)人(ren)員(yuan)棘手的(de)問題(ti),因(yin)為(wei)現有資(zi)料上沒(mei)有專(zhuan)為(wei)戶外10kV電(dian)壓互(hu)感器設計(ji)的保(bao)護(hu)電(dian)器。
110kV電(dian)壓互(hu)感器保(bao)護(hu)電(dian)器的現狀
據(ju)調查,不論(lun)是國內公(gong)開(kai)出(chu)版的(de)變電(dian)所設計(ji)標準(zhun)圖集中,還是很多(duo)設計(ji)單位(wei)所作的(de)變電(dian)所施(shi)工(gong)設計(ji)圖紙(zhi)中,對10kV戶外電(dian)壓互(hu)感器壹次(ci)側(ce)保(bao)護(hu)電(dian)器的選(xuan)擇不外乎(hu)有兩種(zhong)方式(shi):壹(yi)種(zhong)是采用(yong)10kV跌(die)落(luo)式(shi)熔(rong)斷器,另(ling)壹種(zhong)是用(yong)保(bao)護(hu)35kV戶外電(dian)壓互(hu)感器的RW10-35型(xing)高壓限流熔(rong)斷器代替(ti)。
為(wei)了(le)限制(zhi)短(duan)路(lu)電(dian)流,RW10-35,電(dian)壓互(hu)感器使(shi)用(yong)的高壓熔斷器要求熔斷(duan)件具(ju)有壹定的電(dian)阻(zu)值(zhi),而且采用(yong)滅弧(hu)能力(li)較(jiao)強(qiang)的(de)石英(ying)砂(sha)作為(wei)填(tian)料,是壹種(zhong)限流型(xing)熔斷器,RW10-35,這(zhe)種(zhong)高壓熔斷器在(zai)熔(rong)斷(duan)過(guo)程(cheng)中(zhong)會(hui)產生超(chao)過(guo)熔(rong)斷(duan)器額定電(dian)壓數(shu)倍(bei)的(de)過(guo)電(dian)壓。為(wei)了(le)將過(guo)電(dian)壓限制(zhi)在(zai)允(yun)許的(de)範(fan)圍RW10-35,內,對不同(tong)電(dian)壓的(de)高壓熔斷器內熔斷件的(de)特性(xing)都有壹定的要(yao)求。常用(yong)的RN2-10高壓熔斷器熔斷(duan)件的(de)數(shu)據(ju),35kV和(he)10kV用(yong)的熔斷件的(de)電(dian)阻(zu)和(he)長度都(dou)有很大(da)的差(cha)異(yi),當把(ba)35kV限流熔(rong)斷器用(yong)於(yu)10kV時(shi),RW10-35,在(zai)熔(rong)斷(duan)過(guo)程(cheng)中(zhong)會(hui)產生較(jiao)大的(de)過(guo)電(dian)壓,甚(shen)至(zhi)會(hui)擊穿(chuan)電(dian)壓互(hu)感器。《電(dian)力工(gong)程(cheng)電(dian)氣設計(ji)手冊(ce)(電(dian)氣壹(yi)次(ci)部(bu)分(fen))》中(zhong)明(ming)確指出(chu):高壓限流熔(rong)斷器不宜(yi)使(shi)用(yong)在(zai)電(dian)網工(gong)作電(dian)壓低(di)於(yu)熔斷(duan)器額定電(dian)壓的(de)電(dian)網中(zhong)。因(yin)此(ci)10kV電(dian)壓互(hu)感器保(bao)護(hu)熔(rong)斷(duan)器用(yong)RW10-35型(xing)限流熔(rong)斷器代替(ti)是不合適(shi)的。
10kV跌(die)落(luo)式(shi)熔(rong)斷器10KV跌(die)落(luo)保(bao)險(xian)廠家壹(yi)方面由(you)於(yu)熔斷(duan)件截面小,RW10-35,機(ji)械(xie)強(qiang)度(du)低,加(jia)之(zhi)熔(rong)斷(duan)件長期受(shou)張(zhang)力影響(xiang),操(cao)作時(shi)容(rong)易(yi)使(shi)熔(rong)斷件斷(duan)損,可(ke)靠性(xing)差(cha),RW10-35,如(ru)果為了(le)提高機(ji)械(xie)強(qiang)度(du)而加(jia)大熔斷件截面,又(you)會(hui)降低(di)對電(dian)壓互(hu)感器的保(bao)護(hu)作用(yong)。另(ling)壹方(fang)面由(you)於(yu)跌(die)落(luo)式(shi)熔(rong)斷器壹般(ban)不具備(bei)限流功(gong)能,RW10-35高壓熔斷器型號開(kai)斷能力(li)低(di),因(yin)此(ci)也不宜(yi)作為(wei)10kV電(dian)壓互(hu)感器的保(bao)護(hu)電(dian)器。
10kV跌(die)落(luo)式(shi)熔(rong)斷器壹方(fang)面由(you)於(yu)熔斷(duan)件截面小,機(ji)械(xie)強(qiang)度(du)低,加(jia)之(zhi)熔(rong)斷(duan)件長期受(shou)張(zhang)力影響(xiang),操(cao)作時(shi)容(rong)易(yi)使(shi)熔(rong)斷件斷(duan)損,可靠性(xing)差(cha),如果為(wei)了(le)提高機(ji)械(xie)強(qiang)度(du)而加(jia)大熔斷件截面,RW10-35高壓熔斷器又(you)會(hui)降低(di)對電(dian)壓互(hu)感器的保(bao)護(hu)作用(yong)。另(ling)壹方(fang)面由(you)於(yu)跌(die)落(luo)式(shi)熔(rong)斷器壹般(ban)不具備(bei)限流功(gong)能,開斷能(neng)力低(di),因(yin)此(ci)也不宜(yi)作為(wei)10kV電(dian)壓互(hu)感器的保(bao)護(hu)電(dian)器。
2解(jie)決方案(an)
參(can)照現有的RW10-35高壓限流熔(rong)斷器的做(zuo)法,壹種(zhong)專(zhuan)門(men)用(yong)於(yu)10kV電(dian)壓互(hu)感器保(bao)護(hu)的(de)RW□-10型(xing)熔斷器。熔斷(duan)器采用(yong)“T”型(xing)結構,利用(yong)戶內RN2-10型(xing)高壓限流熔(rong)斷器的熔(rong)管,將(jiang)其放在(zai)根據熔(rong)管尺(chi)寸(cun)並滿足(zu)泄(xie)漏比(bi)距要求而特別燒(shao)制(zhi)的(de)瓷套(tao)內,RW10-35,使(shi)之(zhi)既(ji)具(ju)有限流特性(xing),又不使(shi)熔(rong)斷件承(cheng)受張力(li),滿足(zu)了(le)電(dian)壓互(hu)感器的保(bao)護(hu)要(yao)求。
10KV高壓熔斷器的(de)主(zhu)要(yao)特點有:
•熔(rong)斷器允(yun)許水(shui)平或(huo)垂直布置;
•產品按(an)相(xiang)設計(ji),可靈活用(yong)於(yu)三相(xiang)電(dian)壓互(hu)感器或單相(xiang)電(dian)壓互(hu)感器;
•開(kai)斷能力(li)強(qiang),體積(ji)小,安(an)裝維護(hu)方便。
3應(ying)用(yong)及(ji)改(gai)進(jin)
RW□-10高壓熔斷器運行情(qing)況(kuang)良好(hao)。
RW□-10高壓熔斷器在(zai)實(shi)際使(shi)用(yong)過(guo)程(cheng)中(zhong)還可(ke)以從(cong)以下三(san)個(ge)方面加(jia)以改(gai)進(jin):RW10-35,壹(yi)是將高壓熔斷器熔管瓷(ci)套(tao)及(ji)瓷(ci)質(zhi)棒(bang)式(shi)支柱絕緣(yuan)子改(gai)為矽(gui)橡膠(jiao)護套(tao)和(he)支柱絕緣(yuan)子,提高高壓熔斷器的防(fang)汙(wu)性(xing)能,並(bing)減小高壓熔斷器的體積(ji)和(he)重量;二是將高壓熔斷器與避雷(lei)器合二為壹(yi),RW10-35,母(mu)線電(dian)壓互(hu)感器用(yong)熔斷器前側(ce)壹般(ban)都需(xu)要裝(zhuang)設避雷(lei)器,可以將(jiang)RW□-10熔(rong)斷器的支柱絕緣(yuan)子用(yong)避雷(lei)器來代(dai)替(ti);三是將電(dian)壓互(hu)感器與熔(rong)斷器合二為壹(yi),將高壓熔斷器裝配(pei)在(zai)電(dian)壓互(hu)感器絕緣(yuan)套(tao)管內,把(ba)元件集(ji)成,RW10-35,這(zhe)樣(yang)可(ke)以簡(jian)化壹(yi)次(ci)接(jie)線(xian),方(fang)便安(an)裝(zhuang)。
4結(jie)束語(yu)
變電(dian)所10kV配(pei)電(dian)裝置采用(yong)戶外布(bu)置後,電(dian)壓互(hu)感器壹次(ci)側(ce)保(bao)護(hu)電(dian)器的選(xuan)擇成(cheng)為擺在(zai)設計(ji)人(ren)員(yuan)面前(qian)的(de)壹個棘手問題(ti),以往經(jing)常采用(yong)的用(yong)10kV跌(die)落(luo)式(shi)熔(rong)斷器或RW10-35型(xing)限流熔(rong)斷器作為(wei)10kV電(dian)壓互(hu)感器保(bao)護(hu)電(dian)器的方(fang)式(shi)是不合理(li)的,甚(shen)至(zhi)是錯誤的。